'This series of temperature sensors is used to measure the temperature of gas andliquid media. The maximum measurable pressure is 4 MPa.
The thermometer is equipped with an integral welded protective sheath, and is provided withstandard direct-installation threaded process connections or flange connections. It is mainly appliedin pipeline connections, and electrical connections are made through a junction box.
Manufacturing of machinery, equipment and containers
Energy, chemicals and power plants
The food and beverage industry
Sanitation, heating and air conditioning systems
Thermoresistance temperature range: -200C to +600C,thermocouple temperature range: 0C to +1200C.
Integrated transmitter available, programmable andcalibratable. Process connection and probe made ofstainless steel. Electrical connection form: junction box.
Explosion-proof type
Direct output type
| Temperature range | Absence of cervical :-50℃~150℃ Absence of cervical : -50℃~250℃ |
| Measuring element | Thermistors, thermocouples |
| Wiring method | ■Two-wire system, ■3-wire system, ■4-wire system |
| Tolerance values of measuring elements | ■Grade B ■Grade A |
| Output format | Resistance signal or thermocouple signal |
| Electrical connection | ■Ordinary junction box ■Explosion-proof junction box ■Display junction box |
| Explosion-proof protection (optional) | EXdIICT4 isolated explosion-proof |
4...20mA Transmitter Output Type
| Temperature range | Absence of cervical :-50℃~150℃ Absence of cervical : -50℃~250℃ |
| Measuring element | Pt100 thermal resistance |
| Tolerance values of measuring elements | ■Grade B ■Grade A |
| asic configuration | 0 - 150℃ (default) |
| Output format | 4-20mA, 2-wire system |
| Load RA | RA ≤ (UB - 9V) / 0.023A |
| Load impact | ±0.05%/100 Ω |
| power supply | DC 12 - 32V |
| Power protection | Reverse protection |
| Impact of power supply variations | ±0.025%/V |
| Electromagnetic Compatibility (EMC) | Immunity and burst pulses |
| Electrical connection | ■Ordinary junction box ■Explosion-proof junction box ■Display junction box |
| Explosion-proof protection (optional) | EXiaIICT4 intrinsically safe explosion-proof EXdIICT4 isolated explosion-proof |
Environmental conditions
| Ambient temperature and storage temperature | Filter output type: -40°C to 85°C Direct output type -40°C to 120°C |
| Degree of protection | IP 65 is suitable for junction boxes. |
| Response time | < 10 seconds (applicable to sensors with a diameter of 6mm) |
| Materials | stainless steel |
| Seismic resistance | 3g (IEC 60751, standard) |