The FX-103 type heat (cold) quantity integrator is an instrument based on an ARM microprocessor, whichworks in conjunction with various flow transmitters and sensors to measure flow rates. It also works with twoplatinum resistance thermometers (or through a temperature transmitter) to accurately measure the heatquantity of liquid heat carriers or the cold quantity of cold media.

It collects, displays, controls, transmits remotely, communicates and prints various signals such as on-site temperature and flow, forming a digital acquisition system and control system. It is particularly suitablefor trade settlement and measurement management, and can be widely applied in heating systems such asthermal oil boilers and water heating, as well as in building air conditioning heat exchange systems. Itenables online measurement of heat and mass transfer, providing a basis for enterprise energy management.energy consumption measurement and technical economy.


Product Features

  • It is applicable to a wide range of flowmeters and fluid media.

  • It is capable of both liquid heat carrier heat measurement and cold medium cold measurementchannel of standard current transmitter output (source selectable).Automatic conversion of flow units and automatic calculation of the flow coefficient for differential pressure flowmeters.

  • Trade settlement function: Protocol settlement can be enabled for high/low flow,and make-up settlementcan be enabled for power outages.

  • Emergency fault-tolerant function: When the supply/return temperature signals are abnormal, compensationcalculations are performed using emergency parameter values.

  • Debugging and calculation function: Supports viewing the original values of signals from each transmitter/sensor; supports viewing various intermediate parameters in flow and heat calculation, such as density,temperature difference,enthalpy difference,etc.

  • Audit record: Power outage record.

  • Alarm List: Supports recording alarm information of instantaneous or cumulative values such as flow,heat(Cooling) quantity, supply temperature, return temperature, differential pressure/frequency/volume,etc.

  • DCumulative reports: Support daily, monthly and annual reports of cumulative flow and heat (cold) quantity.

  • Communication function: Standard Modbus RTU protocol, supporting RS485 and RS232Ccommunication interfaces.

  • Transmission function: Supports standard current transmission output, and the signal source channel can be selected.



Parameter indicators

Display

Screen128*64 dot matrix monochrome liquid crystal display (LCD)
PrecisionDisplay and measurement accuracy: ±0.2% F.S.
Memory recall accuracy±0.2% F.S.
Instantaneous flow rate unitsm³/h, m³/min, m³/s, L/h, L/min, L/s, t/h, t/min, t/s, kg/h, kg/min, kg/s, km³/h, Nm³/h, kNm³/h
Instantaneous heat unitskJ/h, MJ/h, GJ/h, kCal/h, MCal/h, GCal/h, W, kW, MW, GW


Processor

Adopting a high-performance 32-bit RISC core of ARM Cortex-M3


Input function

Flow channelAnalog signals: 4-20mA, 0-10mA, etc.
Frequency signalFr (range: 0.0 - 5000.0 Hz, low level ≤ 1V, high level ≥ 5V)
Temperature channel0 - 10mA, 4 - 20mA, Pt100 and other signals
Note: Other input signals (such as digital input (DI)) should be specified at the time of ordering.


Output function

Power distribution outputProvides 1 group (F12) of 12VDC and 2 groups (Q24, P24) of 24VDC.

Sensor power supply, maximum output current of a single channel is 30mA, among which the current for flow electricity

The ground of the 24V power distribution for flow Q24 and the 24V power distribution for temperature T24 are common
Transmitter outputSupports 1,Load capacity: 500Ω (maximum)

Relay output

Supports 2 relay outputs, configurable for upper-upper limit, upper limit, lower limit,Lower limit alarm, contact capacity: 3A @ 250VAC / 3A @ 30VDC


Communication function


Communication interfaceTwo communication interfaces, RS232C and RS485, are provided for users to choose from, and both are supported.
     Supports Modbus RTU protocol, baud rate: 1200, 2400, 4800, 9600
Printing interfaceRS232C directly connects to a micro printer, with a baud rate of 1200


Service Guarantee
Service Guarantee
Service Content
Noncon Instrument provides comprehensive pre-sales and after-sales services, including product selection guidance, on-site technical support, installation guidance, and product quality assurance based on customer needs. The company promises a maximum product quality assurance period of 24 months and lifetime free product calibration services to ensure maximum customer benefits.
Product Inquiry
Product Name:
Contact Sales
There are currently no sales available in this region
成都市
成都市

Regional ManagerManager Peng

Contact number86-18030837175

杭州市
杭州市

Regional ManagerManager Zeng

Contact number86-18520508508

西安市
西安市

Regional ManagerManager Jiang

Contact number86-13324545911

武汉市
武汉市

Regional ManagerManager Gao

Contact number86-13871508295

广州市
广州市

Regional ManagerManager Yuan

Contact number86-13711120640

High performance industrial automation instruments
Provide customers with the necessary solutions, intelligent instruments and meters, and achieve sustainability and business goals.