The radar gauge antenna emits extremely narrow microwave pulses, which travel through space at the speed of light. When they hit the surface of the water being measured, some of the electromagnetic waves are reflected back and picked up by the antenna.The plateau series 26G radar water gauge USES a high-speed chip and special software to accurately identify the time interval between the electromagnetic wave emitted and the electromagnetic wave received. This time x the electromagnetic wave velocity ÷2= the distance from the radar antenna to the water surface.

Note:Use radar level meter timing to ensure that the highest water level cannot enter the blind area (shown in figure D).
Application characteristics of water conservancy and hydrology:
The radar level gauge recommended by the industry uses a 26GHz emission frequency and thus has:
The beam Angle is small, the energy is concentrated, has the stronger anti-interference ability, has greatly improved the measurement accuracy and the reliability
Antenna size is small, easy to install and add dust cover and other antenna protection device
Light weight about 1KG, easy to install
Measuring range up to 70 meters, covering large reservoirs and other water level measurement
A variety of output circuit interfaces work with the acquisition system to provide either 485 signals to RTU or 4-20ma signals
Pulse operation mode, radar water level meter transmitted power is very low, no harm to the human body and the environment


Before the installation
Please pay attention to the following to ensure the instrument can be installed correctly:Please allow enough installation space.
Please avoid strong vibration installation.
The illustration shows the installation location:

Note: when a radar antenna emits microwave pulses, it has a certain transmitting Angle.There shall be no obstructions between the lower edge of the antenna and the surface of the medium under test, or in the area radiated by the microwave beam

The power supply voltage
RS485/Modbus
The power supply and Modbus signal lines use a shieldedcable separately. Please refer to the technical data for the specific powersupply voltage range.
The connection method
RS485/Modbus Wiring diagram is as follows:

Please comply with local electrical installation regulations!
Please comply with local health and safety regulations. All operation of the electrical components of the instrument must be performed by professional personnel who have received formal training.
Please check the nameplate of the instrument to ensure that the product specification meets your requirements.Please ensure that the supply voltage is in accordance with the requirements on the instrumentnameplate.
This instrument fully meets the requirements of protection class ip66/67, please ensure the waterproof of cable sealing head. The following figure: