The P208 pressure transmitter sensor adopts advanced microprocessing technology for fully automatic linear error and temperature compensation, ensuring long-term reliability and quality of the product. The circuitry is housed in a die-cast aluminum enclosure (with an external coating of blue epoxy resin). The signal transmission module features a transient voltage protection circuit, enabling it to operate normally in harsh surge voltage environments and maintain a long service life even under significant mechanical loads over extended periods.
It is widely used in process control, liquid level measurement,boiler control, environmentalcontrol, metallurgy, petroleum and petrochemical, water conservancy and power,pharmaceutical and food industries, etc. for process pressure measurement, as well as for themeasurement of process control pressure in explosion-proof industrial sites.
High precision and good reliability
Stability:士0.1% FS/year
Control parameter password lock to ensure security.
LCD digital range display or percentage display
No calibration is required when changing the range or replacing the sensor for maintenance.
Waterproof, dustproof, shockproof, explosion-proof, and corrosion-resistant
The temperature has a minor influence.
Intelligent and miniaturized
Wide measurement range
Software compensation
Self-diagnosis of faults, remote setting communication, remote control
Fieldbus HART protocol communication
| Types of stress | gauge pressure, absolute pressure, negative pressure |
| Range of measurement | 40KPa... 60 MPa (See the measurement range table for details) |
| Output signal | 4...20mA, 0...10V, 0...5V, available as per customer requirements Other output signals |
| Load (Ω) | Current output (two-wire system): mA ≤ (Power supply - 10V) / 0.02A Voltage output (three-wire system): > Maximum output signal / 1mA |
| accuracy level | ±0.2% of full scale, maximum ±0.5% of full scale Optional ±0.1% of full scale range. Based on the standards and test reference conditions, the reference accuracy includes linearity, Lagging, repetitive. Calibration conditions: temperature 20 ± 5°C, atmospheric pressure 101.3 kPa (At a pressure of one atmosphere, which is the local atmospheric pressure) |
| Measured medium | Fluid media such as liquids and gases that are compatible with the contact material |
Measurement range table
| Range code | Nominal range * | Upper limit of range * | Upper limit of pressure resistance * |
| 01 | 0.04 | 0.04 | 0.1 |
| 02 | 0.6 | 0.6 | 1.2 |
| 03 | 1.0 | 1.0 | 2.0 |
| 04 | 1.6 | 1.6 | 0.32 |
| 05 | 2.5 | 2.5 | 0.5 |
| 06 | 4 | 4 | 8 |
| 07 | 6 | 6 | 12 |
| 08 | 10 | 10 | 20 |
| 09 | 16 | 16 | 32 |
| 10 | 25 | 25 | 50 |
| 11 | 40 | 40 | 80 |
| 12 | 60 | 60 | 120 |
* The standard unit is MPa. Pressure units can be provided in KPa, Bar, Psi, etc., and other ranges can also be provided as required.

Regional ManagerManager Peng
Contact number86-18030837175

Regional ManagerManager Zeng
Contact number86-18520508508

Regional ManagerManager Jiang
Contact number86-13324545911

Regional ManagerManager Gao
Contact number86-13871508295

Regional ManagerManager Yuan
Contact number86-13711120640