The P202 flat membrane pressure transmitter is equipped with imported high-precision andhigh-stability anti-corrosion chips. It adopts laser welding technology to seamlessly weld thecore and the stainless steel housing, without a pressure cavity. It is suitable for pressuremeasurement in various environments that are prone to clogging, require hygiene maintenance,and are easy to clean or in a sterile setting.
It is widely applied in food, medicine,brewing and dairy industries.
Water treatment engineering, environmental protection purification
In the fields of petrochemicals, coal, papermaking and other viscous medium areas;
Digital intelligent chip, full-temperature linear temperature compensation;
Exquisite structure, fully stainless steel laser welded structure, strong anti-corrosion ability;
The flat diaphragm structure is suitable for pressure measurement of various viscous media.
Aseptic design, in compliance with 3-A standards.
This product is composed of important components such as circuit boards and sensors.
| Types of stress | gauge pressure, absolute pressure, negative pressure |
| Range of measurement | 40KPa... 4 MPa (See the measurement range table for details) |
| Output signal | 4...20mA, 0...10V, 0...5V, available as per customer requirements Other output signals |
| Load (Ω) | Current output (two-wire system): mA ≤ (power supply - 10V) / 0.02A Voltage output (three-wire system): > Maximum output signal / 1mA |
| accuracy level | ±0.2% of full scale, maximum ±0.5% of full scale Optional ±0.1% of full scale range. Based on the standards and test reference conditions, the reference accuracy includes linearity, Lagging, repetitive. Calibration conditions: temperature 20 ± 5°C, atmospheric pressure 101.3 kPa (At a pressure of one atmosphere, which is the local atmospheric pressure) |
| Measured medium | Fluid media such as liquids and gases that are compatible with the contact material |
Measurement range table
| Range code | Nominal range * | Upper limit of range * | Upper limit of pressure resistance * |
| 01 | 0.04 | 0.04 | 0.1 |
| 02 | 0.6 | 0.6 | 1.2 |
| 03 | 1.0 | 1.0 | 2.0 |
| 04 | 1.6 | 1.6 | 0.32 |
| 05 | 2.5 | 2.5 | 0.5 |
| 06 | 4 | 4 | 8 |
* The standard unit is MPa. Pressure units can be provided in KPa, Bar, Psi, etc., and other ranges can also be provided as required.