The FX-104 type steam thermal energy accumulation meter is an instrumentbased on ARM microprocessor, which works in conjunction with various flowtransmitters and sensors to measure flow and complete the thermal energymeasurement of steam heat carrier.
It collects, displays, controls, transmits remotely, communicates and prints various signalssuch as on-site temperature and flow, forming a digital acquisition system and control system.It is particularly suitable for trade settlement and measurement management, and enables onlinemeasurement of heat transfer, thereby providing a basis for enterprise energy management,energy consumption measurement and technical economy.
The range of applicable flow meters is extensive.
Automatic conversion of flow units and automatic calculation of the flow coefficient of differential pressure flowmeters
Trade settlement function: Protocol settlement can be enabled for high/low traffic.Emergency fault-tolerant function: When the temperature and pressure signals are abnormal,compensation calculations are performed using emergency parameter values
Debugging calculation function: Supports viewing the original values of signals from eachtransmitter/sensor, supports viewing various intermediate parameters in flow and heat energycalculation, such as density, enthalpy, etc.
Audit record: Power outage record.
Alarm list: Supports recording alarm information of instantaneous or cumulative values such asflow, thermal energy, temperature, pressure, differential pressure/frequency/volume, etc
Cumulative reports: Support daily,monthly and annual reports for accumulated flow and heat energyCommunication function: Standard Modbus RTU protocol, supporting RS485 and RS232Ccommunication interfaces.
Transmission function: Supports standard current transmission output, and thesignal source channel can be selected.
Display
| Screen | 128*64 dot matrix monochrome liquid crystal display (LCD) |
| Precision | Display and measurement accuracy: ±0.2% F.S. |
| Memory recall accuracy | ±0.2% F.S. |
| Instantaneous flow rate units | m³/h, m³/min, m³/s, L/h, L/min, L/s, t/h, t/min, t/s, kg/h, kg/min, kg/s, Km³/h, Nm³/h, KNm³/h |
| Instantaneous heat units | kJ/h、MJ/h、GJ/h、kCal/h、MCal/h、GCal/h、W、kW、MW、GW |
Processor
| Adopting a high-performance 32-bit RISC core of ARM Cortex-M3 |
Input function
| Flow channel | Analog signals: 4-20mA, 0-10mA, etc. |
| Frequency signal | Fr (range: 0.0 - 5000.0 Hz, low level ≤ 1V, high level ≥ 5V) |
| Temperature channel | 0 - 10mA, 4 - 20mA, Pt100 and other signals |
| Note: Other input signals (such as digital input (DI)) should be specified at the time of ordering. | |
Output function
| Power distribution output | Provides 1 group (F12) of 12VDC and 2 groups (Q24, P24) of 24VDC. Sensor power supply, maximum output current of a single channel is 30mA, among which the current for flow electricity The ground of the 24V power distribution for flow Q24 and the 24V power distribution for temperature T24 are common |
| Transmitter output | Supports 1,Load capacity: 500Ω (maximum) |
Relay output | Supports 2 relay outputs, configurable for upper-upper limit, upper limit, lower limit,Lower limit alarm, contact capacity: 3A @ 250VAC / 3A @ 30VDC |
Communication function
| Communication interface | Two communication interfaces, RS232C and RS485, are provided for users to choose from, and both are supported. Supports Modbus RTU protocol, baud rate: 1200, 2400, 4800, 9600 |
| Printing interface | RS232C directly connects to a micro printer, with a baud rate of 1200 |

Regional ManagerManager Peng
Contact number86-18030837175

Regional ManagerManager Zeng
Contact number86-18520508508

Regional ManagerManager Jiang
Contact number86-13324545911

Regional ManagerManager Gao
Contact number86-13871508295

Regional ManagerManager Yuan
Contact number86-13711120640